The store will not work correctly in the case when cookies are disabled.
IMPORTANT NOTICE TO ALL FINERFILTERS CUSTOMERS
We are aware of a technical glitch affecting a select number of customers when trying to check out.
The payment screen seems to be constantly loading with no way to input payment details.
We are working to resolve this as soon as possible.
If you are one of the customers affected, please call our customer service team on 01704 807600 who will be more than happy to assist you with processing your order. Our phone lines are open 9am - 4pm. Outside of office hours, please feel free to leave us a LiveChat and someone will get back to you in the morning.
The CS51 Fridge Water Filter operating specifications are as follows:
Flow Rate - 1.9 lpm
Operating Pressure - Min 172 kPa (25 psi) / Max 862 kPa (125 psi)
Operating Temperature - Min 4.4°C / Max 37.8°C
Important: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
Change filter at least every 6 months.
Installation procedure for the CS51 Fridge Water Filter:
The mounting bracket may be installed with the back of the bracket in the up or down position. Screws may be used to attach the bracket to the desired surface or the industrial double-sided tape strip can be cut in half and used to mount the bracket.
The filter must be installed with inlet and outlet ports as labelled. Make sure not to reverse the connections. The shut-off valve should be located in-line somewhere between the incoming water line and the inlet fitting.
Attach the head to the bracket with the screws provided.
Install the cartridge, and make any required connections. Pressurise the system and check for leaks. Flush system in accordance with Performance Data Sheet. Water may run cloudy but will quickly clear
Replacement procedure for the CS51 Fridge Water Filter:
Close shut-off valves before and after the filter head. Depressurise filter.
Grasp the head and cartridge securely, and turn the used cartridge slowly to the left. If the water line has not been properly depressurised, and small discharge of water may occur. Gently pull the cartridge straight out and discard it.
Align tabs of the new cartridge with head and insert the new cartridge into head. Turn the cartridge to the right until the filter stops.
Place the inlet shutoff valves in regular working position. Due to air and carbon fines water may initially run cloudy but will clear. Flush system in accordance with Performance Data Sheet.
Important: It is essential that operation, maintenance and filter replacement be carried out in accordance with manufacturer's recommended procedures and guidelines for this product to perform as advertised. Failure to do so may void the warranty.