To all of our customers - we are currently going through a site relocation commencing 01.10.24 until 07.10.24. We aim for this to have as minimal disruption as possible, however, due to the nature of the move, there may be some slight delays in relation to order dispatch and responding to customer enquiries.
The CS51 Fridge Water Filter operating specifications are as follows:
Flow Rate - 1.9 lpm
Operating Pressure - Min 172 kPa (25 psi) / Max 862 kPa (125 psi)
Operating Temperature - Min 4.4°C / Max 37.8°C
Important: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
Change filter at least every 6 months.
Installation procedure for the CS51 Fridge Water Filter:
The mounting bracket may be installed with the back of the bracket in the up or down position. Screws may be used to attach the bracket to the desired surface or the industrial double-sided tape strip can be cut in half and used to mount the bracket.
The filter must be installed with inlet and outlet ports as labelled. Make sure not to reverse the connections. The shut-off valve should be located in-line somewhere between the incoming water line and the inlet fitting.
Attach the head to the bracket with the screws provided.
Install the cartridge, and make any required connections. Pressurise the system and check for leaks. Flush system in accordance with Performance Data Sheet. Water may run cloudy but will quickly clear
Replacement procedure for the CS51 Fridge Water Filter:
Close shut-off valves before and after the filter head. Depressurise filter.
Grasp the head and cartridge securely, and turn the used cartridge slowly to the left. If the water line has not been properly depressurised, and small discharge of water may occur. Gently pull the cartridge straight out and discard it.
Align tabs of the new cartridge with head and insert the new cartridge into head. Turn the cartridge to the right until the filter stops.
Place the inlet shutoff valves in regular working position. Due to air and carbon fines water may initially run cloudy but will clear. Flush system in accordance with Performance Data Sheet.