EcoSoft 6 Stage Sleek Modern Compact Design Domestic Reverse Osmosis System

Reverse osmosis is the most effective technology of drinking water purification. It reduces 99.8% of impurities, as well as odours, flavours, and viruses making water clear, clean, tasty, and safe for human health, both adults and children. Along with that, the reverse osmosis filter is one of the most cost-effective methods of domestic water purification.

Advantages of the EcoSoft P’URE reverse osmosis filter

  • World leader DOW Filmtec™ membrane (USA)
  • 6 stages of water purification including mineralisation
  • 280 L of drinking water per day
  • Up to 7 L storage tank
  • Delicious taste of water thanks to coconut shell carbon filter
  • 2-handle tap — for purified and mineralised water
  • Both vertical and horizontal mounting possible

Benefits of using the filter

  • Source of clean and safe drinking water
  • Dishes cooked with the water will taste better
  • Coffee beans and tea leaves will release their flavours and aroma easier
  • With the water, you will get the important mineral elements
  • Home appliances (kettle, iron, steam cooker, air humidifier etc.) will be protected from scale

Stages of water purification

The feed water flows through the three pre-filters intended to reduce sediments (rust, sand, silt etc.), chlorine and chlorination by-products, as well as organic matter.

The fourth stage is represented by the reverse osmosis membrane which at the molecular level purifies the water from 99.8% impurities including bacteria and viruses. The purified water is supplied to the storage tank.  

The carbon post-filter is the fifth stage of the water treatment. It contains high-quality activated coconut shell carbon which improves purified water taste and odour.   

The sixth stage of water purification is its mineralization that simultaneously corrects mineral composition of water, pH and its organoleptic properties. It makes the water tasty and enriches the human body with important minerals.

The reverse osmosis filter is intended for treatment of cold water only.

If the time needed to fill the storage tank has increased, it means that the pre-filters are exhausted, and it is necessary to replace them. Delay with the replacement might damage or destroy the membrane. To avoid such critical situations, we strongly recommend replacing the set of pre-filters at least once in 3 months.     

If speed of filtration is decreasing significantly, it is necessary to replace the reverse osmosis membrane. We recommend replacing the membrane at least once a year.

In case there are long breaks (exceeding 2 weeks) in filter application, it is necessary to disinfect the filter (see detailed description of the procedure in the manual). When you are not planning to use the filter during a long period of time, it is recommended to turn off water supply to the filter.

Product Detail

Details

Feed water requirements*

Parameter

Value**

pH

6.5–8.5

TDS, mg/L

<1500

Hardness, meq/L

<10.0

Active chlorine, mg/L

<0.5

Iron, mg/L

<0.3

Manganese, mg/L

<0.1

Chemical oxygen demand, mg O2/L

<5

Total microbial count (TMC), CFU per 1 mg

<50

Coli index

<3

* If the feed water condition does not correspond to the indicated requirements, service life of the membrane and replacement filters might decrease.

** In case of application of the filter for borehole or well water, it is recommended to make a preliminary chemical analysis of the water. If certain indicators exceed the values in the table, it is recommended to install additional pre-filters before the reverse osmosis filter.

Characteristics

Inlet pressure for filter without pump, atm

3–6*

Inlet pressure for filter with pump, atm

2–4.5*

Pressure in storage tank, atm

0.4–0.6**

Temperature of feed water, °C

+4…+30***

Filter weight (basic configuration), kg

6

Temperature of environment limit, °C

+5…+40***

Water supply external connection, inches

thread, ½

Dimensions of filter, HxWxD (basic configuration), mm

350x450x150

Dimensions of tank, HxWxD, mm

350x260x260

* If pressure in the water supply system is lower than indicated, the filter should be supplied with a pump. If pressure in the water supply system is higher than indicated, it is necessary to install a pressure regulator at the inlet before the reverse osmosis filter.

** If pressure is lower or higher than indicated, it is necessary to pump up or release the pressure.

*** If the temperature of feed water is within the range +20…+30 °C, selectiveness of the membrane insignificantly decreases, and capacity increases leading to insignificant growth of the TDS indicator. Application of the filter when the temperature of feed water exceeds +30 °C is not recommended.